谷歌浏览器插件
订阅小程序
在清言上使用

CPI SNS Klystron lifetime and reliability analysis

2017 Eighteenth International Vacuum Electronics Conference (IVEC)(2017)

引用 0|浏览16
暂无评分
摘要
Communications and Power Industries, LLC (CPI) klystrons are populating the majority of sockets in the superconducting linac of the Spallation Neutron Source at Oak Ridge National Laboratory. The klystrons are rated for 550 kW or 700 kW peak at 805 MHz. The klystron production and factory test data provided confidence the device would provide reliable service. Seventy nine sockets have an accumulation over 5.5 million hours of filament operation and 5.0 million hours of high voltage operation to date. Only 3 klystrons have been removed from service since linac conditioning began in 2004.
更多
查看译文
关键词
Klystron,cathode,lifetime,reliability,SNS