On the thermal-hydraulic optimization of DEMO divertor plasma facing components cooling circuit

FUSION ENGINEERING AND DESIGN(2018)

引用 11|浏览1
暂无评分
摘要
Within the framework of the Work Package Divertor, Subproject: Cassette Design and Integration (WPDIV-Cassette) of the EUROfusion action, a research campaign has been jointly carried out by ENEA and University of Palermo to investigate the thermal-hydraulic performances of the DEMO divertor cassette cooling system. Attention has been focussed on the divertor Plasma Facing Components (PFCs) cooling circuit and a parametric analysis has been carried out in order to assess the potential impact of proper layout changes on its thermal-hydraulic performances, mainly in terms of coolant total pressure drop, flow velocity distribution and margin against critical heat flux occurrence. The research activity has been carried out following a theoretical-computational approach based on the finite volume method and adopting a qualified Computational Fluid-Dynamic (CFD) code. Results obtained have allowed to select a revised PFCs cooling circuit configuration, suitable to comply with the prescribed thermal hydraulic limits assumed for the DEMO divertor design. They are reported and critically discussed.
更多
查看译文
关键词
DEMO,Divertor,Plasma facing components,CFD analysis,Thermofluid-dynamics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要