Fluorescence Based Imaging For M-Band Drive Symmetry Measurement In Hohlraum

PHYSICS OF PLASMAS(2016)

引用 4|浏览44
暂无评分
摘要
We describe an experimental technique to measure the drive symmetry of M-band radiation on the capsule in hohlraum. M-band radiation from the corona of the laser-produced gold plasma, especially the laser spot regions in the cavity, was used to pump x-ray fluorescence of a thin layer of Sitracer coated on a solid CH-ball. The fluorescence images were time resolvedly recorded by an x-ray framing camera and the drive asymmetry due to M-band radiation was deduced from these fluorescence images. Moreover, a Si-doped gold cavity was used with the initial purpose of maximizing the fluorescence signal through resonance transitions. Since the Si-plasma expands more rapidly than the gold-plasma, the evolution of drive asymmetry was accelerated in Si-doped hohlraum. Published by AIP Publishing.