谷歌浏览器插件
订阅小程序
在清言上使用

Simultaneous Recombinant 503 Antigen Recovery and Endotoxin Removal from E-Coli M15 Homogenate Using Expanded Bed Adsorption Chromatography

Separation science and technology(2017)

引用 4|浏览9
暂无评分
摘要
This study evaluated the simultaneous recovery of recombinant 503 antigen and endotoxin removal from E. coli homogenate by immobilized metal affinity- expanded bed adsorption chromatography (EBAC), using the non-ionic surfactant Triton X-114 during the washing step. The strategy employed was able to remove more than 99% of endotoxin in all conditions tested, and the lowest residual concentration obtained was 10.22 EU/mL, with a recovery of 503 antigen ranging from 41.4% to 61.1%. Therefore, the procedure of integrating the clarification, recovery of protein, and endotoxin removal into a unit operation exploiting the EBAC was successful.
更多
查看译文
关键词
Endotoxin,expanded bed adsorption chromatography,LPS removal,protein recovery,Triton X-114