Testing requirements for active interrogation systems

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2019)

引用 5|浏览10
暂无评分
摘要
The role of active-interrogation systems for nuclear security is to detect the presence of special nuclear material inside an object by observing the radiation emitted by that object when it has been exposed to known sources of external radiation. Because of the cost, complexity, and the need to avoid irradiating occupants, active-interrogation systems are intended for cargo applications where shielding can prevent detection by passive radiation detection systems. To ensure that active-interrogation systems for detection of special nuclear material are designed and tested to a consistent level of performance, technical standards are needed for evaluating such systems. This paper addresses the testing standards needed for active-interrogation systems to detect high atomic number materials, fissionable materials, and specific special nuclear materials. Because the use of special nuclear material for a testing standard is not practical, this work focuses on the determination of materials that could be used as surrogates in that they provide a similar response as targets of special nuclear materials. The results of this paper, determined through analytic calculations and radiation transport modeling, are based upon scenarios constructed and applied to specific active-interrogation modalities.
更多
查看译文
关键词
Active interrogation,Photofission,High-Z,Differential die-away,Nuclear resonance fluorescence