谷歌浏览器插件
订阅小程序
在清言上使用

Optimization of an Integrated System for Refinery Wastewater Treatment

Toxin reviews(2019)

引用 2|浏览6
暂无评分
摘要
The Fenton and intermittent discharge aerobic bioreactor with continuous flow is used for refinery wastewater treatment. In the Fenton process, the maximum efficiency was obtained at a contact time of 20 min, pH 3, and H2O2/Fe+2 ratio of 15. In the biological treatment, MLSS and aeration time have positive and direct effect on the process efficiency. The maximum COD removal in Fenton, biological, and integrated process was 80.7, 55.14, and 94.21%, respectively. These values for BOD removal were 75.6, 40, and 92.22%, respectively. The type of models for the Fenton and biological treatment were the quadratic and linear model, respectively, according to RSM.
更多
查看译文
关键词
Oil refinery wastewater,advanced oxidation process,Fenton,biological treatment
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要