Indoor air quality assessment with respect to culturable airborne bacteria, total volatile organic compounds, formaldehyde, PM 10 , CO 2 , NO 2 , and O 3 in underground subway stations and parking lots

Air Quality, Atmosphere & Health(2019)

引用 16|浏览9
暂无评分
摘要
We measured the concentrations of indoor pollutants (fine particulate matter (PM 10 )), culturable airborne bacteria (CAB), total volatile organic compounds (TVOCs), formaldehyde (HCHO), CO 2 , NO 2 , and O 3 in subway stations and public parking lots at a national scale in South Korea in order to determine their possible relationships with other underground environmental factors and facility characteristics. Indoor pollutants were sampled at 59 underground facilities with a total of 187 samples in subway stations and parking lots. Kruskal–Wallis and Mann–Whitney analyses were used to examine the relationships between atmospheric pollutants at underground facilities and indoor/outdoor differences in PM 10 and O 3 concentrations. Underground PM 10 concentrations were higher than outdoor concentrations at all underground facilities ( p < 0.001), while underground O 3 concentrations were lower than outdoor O 3 concentrations at all underground facilities ( p < 0.001).
更多
查看译文
关键词
PM10,Culturable airborne bacteria,Carbon dioxide,Nitrogen dioxide,Ozone