A Digital Control Scheme for PSR Flyback Converter in CCM and DCM

IEEE Journal of Emerging and Selected Topics in Power Electronics(2020)

引用 15|浏览16
暂无评分
摘要
Due to the simple structure and low cost, the primary-side-regulation (PSR) flyback converter is widely used in small power applications. As the output voltage is sampled from auxiliary winding in PSR flyback converter, some sampling error exists, especially when continuous conduction mode (CCM) is introduced for higher power. To improve the constant voltage accuracy, a novel digital controlled sampling strategy is proposed. This scheme uses a digital ramp sampling method to sample output voltage in both discontinuous conduction mode (DCM) and CCM, and proposes a voltage adjustment strategy to adjust sampling errors in CCM without weakening the stability in the load-switch process. Finally, the experimental results validate the presented scheme and show that the output voltage error is less than 0.6% in a 20-V, 5-A PSR flyback prototype.
更多
查看译文
关键词
Constant voltage,continuous conduction mode (CCM),digital control,flyback converter,primary-side regulation (PSR)