C. Irmler,H. Aihara,T. Aziz,S. Bacher,S. Bahinipati, E. Barberio, Ti. Baroncelli, To. Baroncelli, A.K. Basith, G. Batignani,A. Bauer,P.K. Behera, V. Bertacchi,S. Bettarini,B. Bhuyan,T. Bilka,F. Bosi,L. Bosisio, A. Bozek, F. Buchsteiner,G. Caria,G. Casarosa,M. Ceccanti,D. Červenkov, T. Czank,N. Dash,M. De Nuccio,Z. Doležal,F. Forti, M. Friedl,B. Gobbo, J.A.M. Grimaldo, K. Hara,T. Higuchi,A. Ishikawa,H.B. Jeon,C. Joo,M. Kaleta,J. Kandra,K.H. Kang, P. Kodyš,T. Kohriki,I. Komarov,M. Kumar,R. Kumar, P. Kvasnička,C. La Licata,K. Lalwani,L. Lanceri, J.Y. Lee,S.C. Lee, Y. Li, J. Libby, T. Lueck, P. Mammini,A. Martini, S.N. Mayekar,G.B. Mohanty,T. Morii, K.R. Nakamura,Z. Natkaniec, Y. Onuki,W. Ostrowicz,A. Paladino,E. Paoloni,H. Park, K. Prasanth, A. Profeti,K.K. Rao,I. Rashevskaya,P.K. Resmi, G. Rizzo,M. Rozanska,D. Sahoo,J. Sasaki,N. Sato, S. Schultschik, C. Schwanda,J. Stypula,J. Suzuki,S. Tanaka,H. Tanigawa,G.N. Taylor,R. Thalmeier,T. Tsuboyama, P. Urquijo,L. Vitale,K. Wan,M. Watanabe,S. Watanuki, I.J. Watson,J. Webb,J. Wiechczynski,S. Williams, H. Yin,L. Zani

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT(2020)

引用 2|浏览78
暂无评分
摘要
The Belle II Silicon Vertex Detector (SVD) was installed recently and has been prepared for physics run at SuperKEKB factory, Tsukuba, Japan. For a reliable operation and data taking of the SVD, a sophisticated and robust run and slow control system has been implemented, which utilizes the Experimental Physics and Industrial Control System (EPICS) framework. EPICS uses client/server and publish/subscribe techniques to communicate between the various sub-systems and computers. The information exchange between the different pieces of software and computers is done by process variables (PVs). These PVs are provided by input/output controllers (IOCs), which communicate and interface with the hardware components. The Belle II SVD slow and run control comprises five groups of subsystems, which are SVD DAQ controller, Flash ADC controller, environmental monitors and interlocks, power supplies and EPICS infrastructure services. In this paper we describe the tasks and the implementation of the individual sub-systems, the interaction between them and the global Belle II run and slow control as well as the first experience from commissioning and initial operation of the SuperKEKB accelerator.
更多
查看译文
关键词
Belle II, Silicon vertex detector, Belle II SVD, Slow control, Run control, EPICS
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要