Shear stiffness in the lower cervical spine: Effect of sequential posterior element injury.

PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE(2020)

引用 4|浏览4
暂无评分
摘要
The aim of this study was to determine the effect of the posterior ligaments and facet joints on the shear stiffness of lower cervical functional spinal units in anterior, posterior, and lateral shear. Five functional spinal units were loaded in anterior, posterior, and right lateral shear up to 100 N using a custom-designed apparatus in a materials testing machine. Specimens were tested in three conditions: intact, with the posterior ligaments severed, and with the facet joints removed. There was a significant decrease in anterior stiffness in the 20-100 N load range from 186 (range: 98-327) N/mm in the intact condition to 105 (range: 78-142) N/mm in the disc-only condition (p = 0.03). Posterior stiffness between these condition decreased significantly from 134 (range: 92-182) N/mm to 119 (range: 83-181) N/mm (p = 0.03). There was no significant effect of posterior ligament removal on shear stiffness. No significant differences were found in the lateral direction or in the 0-20 N range for any direction. Under a 100-N shear load, the facet joints played a significant role in the stiffness of the cervical spine in the anterior-posterior direction, but not in the lateral direction.
更多
查看译文
关键词
Cervical spine,shear,biomechanics,stiffness,kinematics