Conceptual design of JT-60SA edge Thomson scattering diagnostic

JOURNAL OF INSTRUMENTATION(2020)

引用 4|浏览57
暂无评分
摘要
JT-60SA will complement ITER in resolving key issues to finally decide an acceptable DEMO design. Diagnostics play a key role in this mission. The electron temperature and density profiles are measured by a core and an edge Thomson scattering (TS) diagnostics with high spatial resolution, needed to identify the pedestal parameters and small profile structures. The two systems use a common tangential Nd:YAG laser beam path in the plasma equatorial plane. The collection optics for the edge system (low field side) is hosted in a lower oblique port and that for the core system in a horizontal port. The optics fit in the port plug tube and image the scattering volumes into an array of fiber bundles. They both are exposed to a high neutron dose of 10(16) n/cm(2) over 13 years of operation. The optics are supported by a mechanical structure decoupled from the cryostat. A set of filter polychromators with avalanche photodiode (APD) detectors spectrally analyze the scattered radiation. The development of the TS systems is carried out by a joint Japan-EU team. The conceptual design of the edge TS system is presented here. Simulations of the TS signals show acceptable accuracy down to 1 x 10(19) m(-3) electron density, sufficient to measure the edge gradient and even a small region outside the separatrix.
更多
查看译文
关键词
Plasma diagnostics - interferometry, spectroscopy and imaging,Optics,Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs, CMOS imagers, etc),Spectrometers