Comparison of end-tidal carbon monoxide measurements with direct antiglobulin tests in the management of neonatal hyperbilirubinemia

A. L. Elsaie, M. Taleb, A. Nicosia, A. Zangaladze, M. E. Pease, K. Newton,D. L. Schutzman

JOURNAL OF PERINATOLOGY(2020)

引用 13|浏览1
暂无评分
摘要
Objective Determine whether management of neonatal hyperbilirubinemia differs if one used end-tidal carbon monoxide (CO) corrected for ambient CO (ETCO c ) measurements instead of direct antiglobulin test (DAT) results to assess the severity of hemolysis. Study design Retrospective chart review of infants with total bilirubin and ETCO c levels measured from July 2016 to August 2018. The reported treatment is the hypothetical management infants might have received had there been strict adherence to American Academy of Pediatrics guidelines, rather than the actual management they received. Result Only 27.2% of 191 DAT(+) infants were hemolyzing based on ETCO c , while 29.1% of DAT (−) infants were hemolyzing based on ETCO c . Management of 18 (9.4%) infants differed depending if ETCO c or DAT were used to determine hemolysis. Eight fewer infants would have received phototherapy if ETCO c was used. Conclusions ETCO c is a more accurate determinant of hemolysis in the newborn, and its use can lead to less phototherapy.
更多
查看译文
关键词
Diagnosis,Paediatrics,Medicine/Public Health,general,Pediatrics,Pediatric Surgery