Dual Electrochemical Treatments to Improve Properties of Ti6Al4V Alloy.

MATERIALS(2020)

引用 6|浏览2
暂无评分
摘要
Surface treatments are considered as a good alternative to increase biocompatibility and the lifetime of Ti-based alloys used for implants in the human body. The present research reports the comparison of bare and modified Ti6Al4V substrates on hydrophilicity and corrosion resistance properties in body fluid environment at 37 degrees C. Several surface treatments were conducted separately to obtain either a porous oxide layer using nanostructuration (N) in ethylene glycol containing fluoride solution, or bulk oxide thin films through heat treatment at 450 degrees C for 3 h (HT), or electrochemical oxidation at 1 V for 3 h (EO), as well as combined treatments (N-HT and N-EO). In-situ X-ray diffraction and ex-situ transmission electron microscopy have shown that heat treatment gave first rise to the formation of a 30 nm thick amorphous layer which crystallized in rutile around 620 degrees C. Electrochemical oxidations gave rise to a 10 nm thick amorphous film on the top of the surface (EO) or below the amorphous nanotube layer (N-EO). Dual treated samples presented similar results with a more stable behavior for N-EO. Finally, for both corrosion and hydrophilicity points of view, the new combined treatment to get a total amorphous N-EO sample seems to be the best and even better than the partially crystallized N-HT sample.
更多
查看译文
关键词
TiO2 nanotubes,bulk thermal treatment,bulk oxide layer,corrosion,wettability