Pohang Accelerator Laboratory (PAL) is building the 4th generation X-ray free electron laser (XFEL). The Injection Test Facility (ITF) is a test facility established to improve the functions of the laser gun and pre-injector to be installed in XFEL. To improve the effects of ITF, two factors are required. The first is to be able to generate low-emittance electron beams stably at the laser gun, and the second is to control increasing emittance by space charge effect by accelerating electron beams with high energy at the pre-injector. In this way, high-quality electron beams can be materialized. Various beam diagnostics are installed in the accelerator system for beam diagnostics and measurements. Five kinds of beam diagnostics were installed in the PAL-ITF. These are (1) ICT and (2) Faraday Cup to measure current and electrons charge, (3) Stripline BPM to measure the location of beams, (4) a YAG/OTR Screen Monitor to measure beam energy and transverse profile motion, (5) a Wire Scanner to measure beam size. In this paper, the purposes and properties of each diagnostic unit and measurement results are introduced.