Effect of Gas Injection during LHCD Experiments in ITER-Relevant Coupling Conditions

M. Goniche, A. Ekedahl, K. Rantamäki, J. Mailloux, V. Petrzilka,G. Arnoux, Y. Baranov, L. Delpech,P. De Vries,K. Erents,P. Jacquet,S. Jachmich, K. Kirov, X. Litaudon,M.-L. Mayoral,J. Ongena, A. Sirinelli,M. Stamp, L. Zabeo,K.-D. Zastrow

semanticscholar(2008)

引用 0|浏览0
暂无评分
摘要
LHCD experiments were carried out on the JET tokama k in ITER-relevant conditions which include: low (δ~0.22) and high ( δ~0.45) triangularity ELMy plasmas, high safety fact or (q95=4.0-6.8) and gaps between the separatrix and the antenna varying between 0.08 m and 0.16m. Good coupling conditions, throughout the entire an ten a, are found when the power injection is assist ed by local D2 gas feed. The beneficial modification of the SOL i n the flux tubes passing in front of the antenna is documented by measurements of a reciprocating Langmuir probe. This allowed to couple up to 3.1MW, with a gap of 0.15m, corresponding to a power density of 1 5MW/m, but 22 MW/m on half of the antenna which is close to the power density required at 3.7GHz for I TER. Modeling of the modification of the SOL by LH power absorption was performed with the EDGE2D fluid code. Flat j sat/density profiles similar to experimental ones are obtained when a small fraction of the LH power is supposed to be absorbed in a ~20mm thick l ayer in front of the antenna. The parallel heat flux (F // ) on a plasma-facing component due to LH power diss ipation in th SOL is computed from infra-red data. The strong dependence of F// with the injected LH power gives further evidence o f the LH-induced density modification. It is conclude d that with optimized gas injection F // in H mode should not exceed 5MW/m at maximum power density (25MW/m ). The effect of large gap and gas injection on LH cur rent drive efficiency was studied in L-mode discharges for which the real-time control was used in order to keep the loop voltage constant (0.2V) and leave the plasma current floating. The plasma current of the large gap/gas injection case is lower than that the small gap/no injection case by 5%. At the same time a sig nificant increase of density fluctuations measured by reflectometry at the plasma periphery is measured f or the large gap/gas injection case. The effect of the gas injection on the energy confi nement is investigated. No effect on the global confinement or on the neutron rate was observed in the advanced tokamak scenario, Only a slight modif icat on of the type-I ELMs amplitude and frequency was obse rved when the connected pipe puffed gas. The confinement degrades with the line-averaged density ormalized to the Greenwald density, identically f or pulses for which the connected gas injection is used or no t.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要