Background: Heparin-bonded polytetrafluoroethylene grafts were marketed to improve hemodialysis access outcomes but are twice the cost of standard polytetrafluoroethylene. We launched a randomized trial of heparin-bonded polytetrafluoroethylene versus standard polytetrafluoroethylene for hemodialysis access to compare patency. Since the trial began, additional studies were published with heterogeneous findings. We performed an interim analysis by Bayesian methods using prior probability from meta-analysis of existing literature. Methods: NCT01601873 is a randomized, blinded trial of heparin-bonded polytetrafluoroethylene versus standard polytetrafluoroethylene for dialysis access at 5 sites. Planned sample size was 200 with 1-year primary patency as the primary endpoint. At interim analysis (50% of sample size at 1 year), we also performed a meta analysis for 1-year primary patency with a random effects model to compute summary rate ratio and standard error estimates. Meta-analysis estimates formed a prior probability for a Bayesian Cox regression model, and trial data were reanalyzed to develop posterior probability of heparin-bonded polytetrafluoroethylene effectiveness at our hypothesized effect size. Futility analysis was conducted using posterior probability estimates. Results: One hundred and five patients were enrolled at the time of interim analysis. One-year primary patency was 34.9% in the heparin-bonded-polytetrafluoroethylene group vs 32.7% in the standardpolytetrafluoroethylene group (P = .884). Summary rate ratio from the meta-analysis (1,209 patients) was 0.87 favoring heparin-bonded polytetrafluoroethylene (P = .33). Posterior hazard ratio from Cox regression was 0.90 (credible interval 0.70-1.13) favoring heparin-bonded polytetrafluoroethylene, which was not significant. Bayesian posterior probability of the a priori hypothesized 20% better patency with heparin-bonded polytetrafluoroethylene was 24%. Sample size to detect superiority with the small observed effect size would require about 3,800 subjects. Conclusion: Current evidence does not demonstrate sufficiently large benefit of heparin-bonded polytetrafluoroethylene over standard polytetrafluoroethylene for dialysis access to justify higher cost. Given similar 1-year patency rates, a conclusive finding of superiority was judged to be infeasible, and the trial was stopped for futility. (C) 2020 The Authors. Published by Elsevier Inc.
更多
查看译文
关键词
Peripherally Inserted Central Catheters,Hemodialysis Vascular Access
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要