Heart Failure Hospitalizations And Costs In Icd/Crt-D Recipients Following Replacement Or Upgrade: The Decode Registry

ESC HEART FAILURE(2020)

引用 2|浏览42
暂无评分
摘要
Aims The aim of this study is to report heart failure hospitalization (HFH) rates and associated costs within 12 months following implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) device replacement or upgrade from ICD to CRT-D.Methods and results The DEtect long-term COmplications after icD rEplacement (DECODE) was a prospective, single-arm, multicentre cohort study that explored complications in ICD/CRT-D recipients. All clinical and survival data at 12 months were prospectively analysed. For each adjudicated HFH, admission and discharge dates and ICD-9-CM diagnosis and procedure codes were recorded. The reimbursement for each HFH was calculated for each diagnosis-related group code. Between 2013 and 2015, 983 patients (mean age 71 years, male 76%, mean left ventricular ejection fraction 35%, and New York Heart Association Class I/II 75.6%) were enrolled. Patients underwent device replacement (900; 91.6%, 446 ICD/454 CRT-D) or ICD upgrade to CRT-D (83; 8.4%). Post-replacement hospitalizations occurred in 220 patients, with the primary discharge diagnosis identifying cardiovascular causes in 175 patients (80%). Fifty-five (5.6%) patients experienced at least one HFH. Overall, 91 HFH events occurred (9.6% event rate, 95% confidence interval: 7.7-11.7) in 70 patients; 66 (6.7%) patients died, 40 (60.6%) of cardiovascular causes. The HFH rate was significantly higher following upgrades, and the occurrence of HFH was associated with an 11-fold increased mortality risk (95% confidence interval: 5.9-20.5, P < 0.0001). Medical diagnosis-related group accounted for 91.2% of HFH; the mean cost per HFH was euro 5662 +/- 9497, and the mean cost per patient was euro 9369 +/- 12 687. On multivariate analysis, predictors of HFH were atrial fibrillation, chronic kidney disease, and all-cause hospitalization within 30 days prior to the procedure.Conclusions In the DECODE registry, HFH and mortality rates in the year following ICD/CRT-D replacement or upgrade were low. In this particular subset, underlying cardiac disease was the main driver of HFH, mortality, and higher healthcare expenditures.
更多
查看译文
关键词
Cardiac resynchronization therapy, Costs, Device replacement, Heart failure hospitalization, Implantable cardioverter defibrillator
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要