Ion-Selective Sensors Based on Laser-Induced Graphene for Evaluating Human Hydration Levels Using Urine Samples
ADVANCED MATERIALS TECHNOLOGIES(2020)
摘要
Complex graphene electrode fabrication protocols including conventional chemical vapor deposition and graphene transfer techniques as well as more recent solution-phase printing and postprint annealing methods have hindered the wide-scale implementation of electrochemical devices including solid-state ion-selective electrodes (ISEs). Herein, a facile graphene ISE fabrication technique that utilizes laser induced graphene (LIG), formed by converting polyimide into graphene by a CO2 laser and functionalization with ammonium ion (NH4+) and potassium ion (K+) ion-selective membranes, is demonstrated. The electrochemical LIG ISEs exhibit a wide sensing range (0.1 x 10(-3)-150 x 10(-3) m for NH4+ and 0.3 x 10(-3)-150 x 10(-3) m for K+) with high stability (minimal drop in signal after 3 months of storage) across a wide pH range (3.5-9.0). The LIG ISEs are also able to monitor the concentrations of NH4+ and K+ in urine samples (29-51% and 17-61% increase for the younger and older patient; respectively, after dehydration induction), which correlate well with conventional hydration status measurements. Hence, these results demonstrate a facile method to perform in-field ion sensing and are the first steps in creating a protocol for quantifying hydration levels through urine testing in human subjects.
更多查看译文
关键词
graphene,hydration,potentiometry,solid-contact ion-selective electrode (ISE),urinalysis