His Bundle Pacing Shows Similar Ventricular Electrical Activation As Sinus: Selective And Nonselective His Pacing Indistinguishable

AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY(2021)

引用 3|浏览12
暂无评分
摘要
His bundle pacing utilizes the His-Purkinje system to produce more physiological activation compared with traditional pacing therapies, but differences in electrical activation between pacing techniques are not yet quantified in terms of activation pattern. Furthermore, clinicians distinguish between selective and nonselective His pacing, but measurable differences in electrical activation remain to be seen. Hearts isolated from seven dogs were perfused using the Langendorff method. Electrograms were recorded using two 64-electrode basket catheters in the ventricles and a 128-electrode sock situated around the ventricles during sinus rhythm (right atrial pacing), right ventricular (RV) pacing, biventricular cardiac resynchronization therapy (biV-CRT), selective His pacing (selective capture of the His bundle), and nonselective His pacing (capture of nearby myocardium and His bundle). Activation maps were generated from these electrograms. Total activation time (TAT) was measured from the activation maps, and QRS duration was measured from a one-lead pseudo-ECG. Results showed that TAT, QRS duration, and activation sequence were most similar between sinus, selective, and nonselective His pacing. Bland-Altman analyses showed highest levels of similarity between all combinations of sinus, selective, and nonselective His pacing. RV and biV-CRT activation patterns were distinct from sinus and had significantly longer TAT and QRS duration. Cumulative activation graphs were most similar between sinus, selective, and nonselective His pacing. In conclusion, selective pacing and nonselective His bundle pacing are more similar to sinus compared with RV and biV-CRT pacing. Furthermore, selective pacing and nonselective His bundle pacing are not significantly different electrically.NEW & NOTEWORTHY Our high-density epicardial and endocardial electrical mapping study demonstrated that selective pacing and nonselective His bundle pacing are more electrically similar to sinus rhythm compared with right ventricular and biventricular cardiac resynchronization therapy pacing. Furthermore, small differences between selective and nonselective His bundle pacing, specifically a wider QRS in nonselective His pacing, do not translate into significant differences in the global activation pattern.
更多
查看译文
关键词
His bundle pacing, His Purkinje system, pacemaker, physiological pacing
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要