Towards the Removal of Antibiotics Detected in Wastewaters in the POCTEFA Territory: Occurrence and TiO2 Photocatalytic Pilot-Scale Plant Performance

WATER(2020)

引用 22|浏览14
暂无评分
摘要
This research aims to assess the presence of four antibiotic compounds detected in the influent and effluent of wastewater treatment plants (WWTPs) in the POCTEFA territory (north of Spain and south of France) during the period of 2018-2019, and to relate the removal of antibiotic compounds with the processes used in the WWTPs. The performance of a photocatalytic TiO2/UV-VIS pilot-scale plant was then evaluated for the degradation of selected antibiotics previously detected in urban treated effluent. The main results reflect that azithromycin had the highest mass loadings (11.3 g/day per 1000 inhabitants) in the influent of one of the selected WWTPs. The results also show considerable differences in the extent of antibiotics removal in WWTPs ranging from 100% for sulfadiazine to practically 0% for trimethoprim. Finally, the photocatalytic TiO2/UV-VIS pilot-scale plant achieved the removal of the four antibiotics after 240 min of treatment from 78%-80% for trimethoprim and enrofloxacin, up to 100% for amoxicillin, sulfadiazine and azithromycin. The catalyst recovery via mechanical coagulation-flocculation-decantation was almost total. The Ti concentration in the effluent of the TiO2/UV-VIS pilot-scale plant was lower than 0.1% (w/w), and its release into the environment was subsequently minimized.
更多
查看译文
关键词
antibiotics,wastewater,removal efficiency,photocatalysis,slurry reactor