Experimental study on a floating scroll-type compressor driving a precooled JT cryocooler

APPLIED THERMAL ENGINEERING(2020)

引用 10|浏览3
暂无评分
摘要
The performance of the compressor directly affects the energy and space usage of a Joule-Thomson cryocooler. Characterized by simplicity and high pressure ratio, a single-stage oil-free floating scroll-type compressor with a back pressure regulating valve is introduced to drive the precooled Joule-Thomson cryocooler to approach liquid helium temperature. Cool down and pressure regulation processes of this Joule-Thomson cryocooler are presented. The stable cooling capacity at liquid helium temperature is achieved by which the availability of this compressor is verified. By regulating the back pressure of the compressor, it is found that there exists an optimal back pressure with which the exergetic efficiency of the compressor can be maximized keeping a stable performance.
更多
查看译文
关键词
Floating scroll-type compressor,Back pressure,Joule-Thomson cryocooler,Liquid helium temperature