Design Of A Multi-Voltage Probe System For Icrf Antenna Coupling Resistance Measurement On East

PLASMA SCIENCE & TECHNOLOGY(2020)

引用 0|浏览17
暂无评分
摘要
A multi-voltage probe array system is designed to measure the coupling resistance of an ion cyclotron resonance frequency antenna. In the process of the antenna coupling resistance data extraction, the minimization algorithm, the original Levenberg-Marquardt algorithm, is replaced by the Broyden-Fletcher-Goldfarb-Shanno algorithm to achieve more stable and accurate results. Moreover, a simple model of the multi-voltage probe array was applied to simulate the performance of the Kalman filter, and to optimize the distance and position of the probes and probe number to mitigate the influence of the system noise on the rebuilt results. During the EAST experiment in 2019, a four-voltage probe array was applied to measure the coupling resistance of line 6 during high confined mode discharge. The measurement results by the multi-voltage probe array system and the voltage/current probe pair show a good agreement.
更多
查看译文
关键词
EAST, ICRF, BFGS algorithm, multi-voltage probe, coupling resistance
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要