Exhaled-breath Temperature And Spirometer Airflow Dynamics Following Cold-water Ingestion In Healthy Subjects: 2896 Board #357 May 29 10:30 AM - 12:00 PM

Medicine and Science in Sports and Exercise(2020)

引用 0|浏览2
暂无评分
摘要
PURPOSE: Ingesting cold-water evokes decreases in spirometric indices of pulmonary function. However, given that most commercial spirometers assume an exhaled-breath temperature (EBT) of 37 °C, a cold-water-induced decrease in EBT may influence the accuracy of flow-volume measurements. Accordingly, the aims of this study were: i) to assess whether cold-water ingestion was sufficient to reduce EBT in healthy subjects; and ii) to model the influence of EBT on pneumotachograph airflow dynamics. METHODS: Ten healthy, recreationally-active adults (5 male, 5 female), with normal pulmonary function, volunteered to participate (age=36±7 y; mass=87.4±31.8 kg; stature=1.74±0.8 m). In a randomized crossover design, subjects consumed either 1000 mL of refrigerated water (2.1±0.64 °C) or water at room temperature (19.4±0.5 °C), with exhaled-breath temperature assessed (via the tidal breathing method) at baseline and at 5, 10, 15, and 30 min post-ingestion. The influence of exhaled-breath temperature on the measurement characteristics of a non-heated pneumotachograph, was modelled using computational fluid dynamics (CFD). RESULTS: Baseline EBT was not different between the two conditions (33.8±0.4 vs. 33.7±0.54 °C; p=0.269, d=0.25). Following the ingestion of cold-water, EBT fell below baseline and remained so until the final measure at 30 min (p<0.01). When compared to water at room temperature, EBT was significantly lower following the ingestion of cold-water at 5 min (31.7±1.1 vs. 33.0±0.9 °C; p<0.001, d=1.34), 10 min (32.6±0.6 vs. 33.2±0.6 °C; p<0.001, d=1.06), and 15 min post-ingestion (32.5±0.6 vs. 33.3±0.5 °C; p<0.001, d=1.46). A mean decrease in EBT of 2.1 °C (as observed acutely following cold-water ingestion) was modelled to under-predict flow by 0.84% and volume by 0.78%. CONCLUSIONS: Cold-water reduces exhaled-breath temperature for at least 30 min post-ingestion, and to a greater extent than water at room-temperature. The mean decrease in EBT resulted in a negligible effect on calculated flow-volume variables. Accordingly, a measured change in lung function that follows cold-water ingestion likely has a physiological explanation which warrants further study. These data may also have implications for the clinical assessment of EBT in monitoring pathological processes of the airway.
更多
查看译文
关键词
spirometer airflow dynamics,ingestion,exhaled-breath,cold-water
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要