Local Structure Effects On Pressure Drop In Slender Fixed Beds Of Spheres

CHEMIE INGENIEUR TECHNIK(2021)

引用 13|浏览0
暂无评分
摘要
For slender fixed beds, the void fraction and flow properties are complex topics. Different factors can influence the local bed structure. For statistical analysis, 2800 fixed beds have been generated and the impact of friction factor and reactor-to-particle diameter ratio on the distribution has been shown. With particle-resolved computational fluid dynamics, all local structure effects are taken into account for the flow simulations. Pressure drop measurements and simulations showed that these effects can lead to areas with low flow resistance, leading to overestimated pressure drop by typical correlations up to 85 %.
更多
查看译文
关键词
Computational fluid dynamics, Fixed bed reactor, Pressure drop, Rigid body approach, Synthetic fixed beds
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要