Aseptic Stethoscope Barriers Prevent C difficile Transmission In Vitro
Mayo Clinic Proceedings: Innovations, Quality & Outcomes(2021)
摘要
Objective
To evaluate whether Clostridioides (formerly Clostridium) difficile–contaminated stethoscope diaphragms remained aseptic by the placement of an aseptic diaphragm barrier.
Methods
On November 1, 2019, fresh cultures of C difficile were diluted to 107 colony-forming units (CFU)/mL and used to inoculate 16 stethoscope diaphragms; 8 had an aseptic diaphragm barrier applied and 8 served as nonbarrier controls. Contaminated stethoscopes were anaerobically incubated, then swabbed at 15 and 30 minutes, 2 and 4 hours, and 1, 2, 3, and 7 days after inoculation and subsequently plated onto blood, chocolate, and cycloserine-cefoxitin fructose agar. Plates were incubated for 48 hours and on November 9, 2019, the resulting colonies were manually counted. Statistical analyses (RStudio, version 1.0.153) used analysis of variance with post hoc Tukey honestly significant difference.
Results
Overall, mean colony count was 33 CFU on stethoscopes without barriers vs zero on those with barriers (P≤.05). Growth was greatest at 48 hours, with colony counts as high as 160 CFU. The presence of the barrier resulted in no growth in 100% of stethoscope diaphragms for up to 1 week.
Conclusion
We found that stethoscope diaphragm barriers provide an aseptic patient contact point, thus reducing the potential for transmission of C difficile during the physical examination. In critical care environments, in which many hospitals use acoustically inferior disposable stethoscopes, the option of a disposable aseptic stethoscope barrier may allow high-quality auscultation while reducing the potential for pathogen transmission.
更多查看译文
关键词
CCFA,CDI,CFU,MDRO,VRE
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要