Multi-Length Scale Characterization Of Compression On Metal Foam Flow-Field Based Fuel Cells Using X-Ray Computed Tomography And Neutron Radiography

ENERGY CONVERSION AND MANAGEMENT(2021)

引用 18|浏览7
暂无评分
摘要
The mechanical compression of metal foam flow-field based polymer electrolyte fuel cells (PEFCs) is critical in determining the interfacial contact resistance with gas diffusion layers (GDLs), reactant flow and water management. The distinct scale between the pore structure of metal foams and the entire flow-field warrant a multi length scale characterization that combines ex-situ tests of compressed metal foam samples and in-operando analysis of operating PEFCs using X-ray computed tomography (CT) and neutron radiography. An optimal 'medium' compression was found to deliver a peak power density of 853 mW cm-2. The X-ray CT data indicates that the compression process significantly decreases the mean pore size and narrows the pore size distribution of metal foams. Simulation results suggest compressing metal foam increases the pressure drop and gas velocity, improving the convective liquid water removal. This is in agreement with the neutron imaging results that demonstrates an increase in the mass of accumulated liquid water with minimum compression compared to the medium and maximum compression cases. The results show that a balance between Ohmic resistance, water removal capacity and parasitic power is imperative for the optimal performance of metal foam based PEFCs.Superscript/Subscript Available更多
查看译文
关键词
Fuel cell, Compression effect, Metal foam microstructure, Neutron radiography, X-ray CT