谷歌浏览器插件
订阅小程序
在清言上使用

Monitoring of perfusion quality and prediction of donor heart function during ex-vivo machine perfusion by myocardial microcirculation versus surrogate parameters

The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation(2021)

引用 12|浏览7
暂无评分
摘要
Currently, lactate (Lac) is used to evaluate machine perfusion (MP) of hearts, donated after circulatory death (DCD). We hypothesize that monitoring of myocardial microcirculation (mLDP) by Laser-Doppler-Perfusion is superior to Lac to evaluate perfusion and predict contractility. In a pig model, DCD-hearts were perfused 4 hours followed by reperfusion and left ventricular contractility measurement. Lac and mLDP were measured every 30 min in successfully (N = 9) and unsuccessfully (N = 7) maintained hearts. Successfully maintained hearts showed decreasing Lac (5.6 to 2.8 mmol/L) and slightly downregulated (92%) mLDP. In unsuccessfully maintained hearts Lac first decreased (5.1 to 3.8 mmol/L) followed by increase and mLDP dropped to 39%. In a single-variable regression only mLDP showed a significant r(2) for systolic (0.514, p = 0.045) and diastolic (0.501, p = 0.049) parameters. The combination of mLDP and Lac (r(2) = 0.876, p = 0.005) showed best results. mLDP seems to be superior to Lac to show perfusion disorders and predict DCD-heart contractility. (C) 2021 International Society for Heart and Lung Transplantation. All rights reserved.