Concordance Between Estimated Glomerular Filtration Rate Using Equations And That Measured Using An Imaging Method

REVISTA MEDICA DE CHILE(2021)

引用 2|浏览1
暂无评分
摘要
Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 54 +/- 17 years (47% women) GFR was estimated using the MDRD-4, CKD-EPI and the body surface adjusted Cockroft Gault equation. GFR was also measured using a radionuclide imaging method with (99)mTc-DTPA. The concordance between estimated and measured GFR was calculated using Lin's concordance coefficient and Bland and Altman plots. Results: Average GFR values obtained with CKD-EPI, MDRD-4, body surface adjusted Cockroft Gault equation and (99)mTc-DTPA imaging were 75.9 +/- 26.6, 76.3 +/- 28.8, 77.1 +/- 31.6 and 77.9 +/- 28.4 ml/min/1.73 m(2), respectively. There was no significant difference in means and 29% of participants had a GFR < 60 ml/min/1.73 m(2) by CKD-EPI. The correlation was good between equations, but acceptable when compared with the (99)mTc-DTPA imaging. The weighted kappa between CBEs was good, but low when comparing CBEs with measured GFR. The Lin's concordance coefficient between estimated and measured GFR was low. Conclusions: GFR measured by (99)mTc-DTPA radionuclide imaging has a low correlation and poor concordance with estimations using CBE.
更多
查看译文
关键词
Glomerular Filtration Rate, Kidney Function Tests, Radionuclide Imaging, Renal Insufficiency, Chronic