Quality Control Tests Of The Front-End Optical Link Components For The Atlas Liquid Argon Calorimeter Phase-1 Upgrade

B. Deng,J. Thomas, L. Zhang,E. Baker, A. Barsallo,M. L. Bleile,C. Chen,I. Cohen, E. Cruda, J. Fang, N. Feng,D. Gong,S. Hou,X. Huang, T. Lozano-Brown,C. Liu,T. Liu,A. Muhammad, L. A. Murphy, P. M. Price, J. H. Ray, C. Rhoades, A. H. Santhi, D. Sela,H. Sun,J. Wang,Z. Wang,L. Xiao,W. Zhang,X. Zhao,J. Ye

JOURNAL OF INSTRUMENTATION(2021)

引用 0|浏览8
暂无评分
摘要
We present the procedures and results of the quality control tests for the front-end optical link components in the ATLAS Liquid Argon Calorimeter Phase-1 upgrade. The components include a Vertical-Cavity Surface-Emitting Laser (VCSEL) driver ASIC LOCld, custom optical transmitter/transceiver modules MTx/MTRx, and a transmitter ASIC LOCx2. LOCld, MTx, and LOCx2 each contain two channels with the same structure, while MTRx has a transmitter channel and a receiver channel. Each channel is tested at 5.12 Gbps. A total of 5341 LOCld chips, 3275 MTx modules, 797 MTRx modules, and 3198 LOCx2 chips are qualified. The yields are 73.9%, 98.0%, 98.4%, and 61.9% for LOCld, LOCx2, MTx, and MTRx, respectively.
更多
查看译文
关键词
Analogue electronic circuits, Front-end electronics for detector readout, Optical de-tector readout concepts