谷歌浏览器插件
订阅小程序
在清言上使用

Intraoperative Automated Radiographic Visualization Tool Allows for Higher Accuracy of Cam Lesion Resection when Used by Novice Surgeons for Arthroscopic Femoroplasty: Lowering the Learning Curve

Arthroscopy(2022)

引用 7|浏览8
暂无评分
摘要
Purpose: To compare the accuracy of conventional fluoroscopy versus an intraoperative radiographic visualization tool in assisting a novice and experienced hip arthroscopist in comprehensive cam correction to a desired alpha angle (AA). Methods: A cadaveric study was performed using 28 hemi-pelvises with cam-type deformity (AA > 55 degrees) measured on anteroposterior, lateral, and Dunn-view radiographs. Two fellowship-trained hip arthroscopists each performed 14 arthroscopic femoroplasties. The specimens were randomly assigned: 14 of the procedures were performed by the experienced surgeon, with 7 using the automated radiographic visualization tool (Guided Femoroplasty) and 7 using routine fluoroscopy (Control). The same number of hips was assigned to the novice surgeon, completing 7 femoroplasties with and without the visualization tool. Each hip was imaged before and after femoroplasty in 6 different positions using intraoperative fluoroscopy to evaluate head-neck offset. Femoroplasty AAs were compared between groups with and without visualization tool use, as well as between surgeons. One-way analysis of variance analysis was performed to evaluate the consistency of cam resection. Results: For the experienced hip arthroscopist, comparison of Guide Femoroplasty and Control groups resulted in similar accuracy when compared to the controls, with post-femoroplasty AA averages ranging from 41.4 degrees +/- 3.8 degrees to 44.8 degrees +/- 2.8 degrees (P = .511) and 40.2 degrees +/- 5.3 degrees to 45.6 degrees +/- 2.2 degrees (P = .225), respectively. For the novice hip arthroscopist, the Guided Femoroplasty group had higher accuracy, with post-femoroplasty AA averages ranging from 42.8 degrees +/- 2.6 degrees to 46.1 degrees +/- 7.2 degrees (P = .689) with and 39.8 degrees +/- 3.1 degrees to 51.9 degrees +/- 8.1 degrees (P = .001) without the visualization tool. Comparison of procedure time did not show any statistically significant difference between the use of the radiographic visualization tool and controls for either surgeon (P > .05 for all). Conclusions: Femoroplasty with and without the use of automated radiographic visualization tool results in accurate cam resection when used by both the experienced and novice surgeon. However, higher accuracy was observed when resecting to a desired AA performed by a novice surgeon using the visualization tool. Additionally, use of the visualization tool did not result in longer procedure times for either surgeon.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要