Cell saver blood is typically washed with normal saline (NS); however, recent studies have reported decreased red blood cell hemolysis and increased platelet function when a more physiologic washing solution, such as Plasma-Lyte A (PL-A) is used. We evaluated the in vitro and in vivo effects of NS compared to PL-A as washing solutions for cell saver blood in pediatric cardiac surgery. Cell saver blood was re-infused for up to 24 hours post-collection. Laboratory and clinical data were collected from infants receiving cell saver washed with either NS ( = 20) or PL-A ( = 21). Compositions of the cell saver blood were compared between groups at 5 in vitro time points and in vivo patient blood at 24 hours post-bypass. Although there were differences in in vitro laboratory values between groups; 24 hours post-bypass, in vivo results were similar. Our data supports 24-hour reinfusion of cell saver washed with either NS versus PL-A in pediatric cardiac surgery patients, and provides data on the differences in cell saver composition to guide future studies.