谷歌浏览器插件
订阅小程序
在清言上使用

Temporal Diagnostics from Photons: the Experience with the PALM

Advances in X-ray Free-Electron Lasers Instrumentation IV(2018)

引用 0|浏览10
暂无评分
摘要
The Photon Arrival and Length Monitor (PALM), a THz streak camera device developed by PSI for non-destructive hard x-ray measurements of photon pulse length and arrival time versus a pump laser[1], was brought to the SACLA XFEL[2] in Japan in a cross-calibration temporal diagnostics campaign after an initial experiment where only the PALM was being used[3]. The device was used with 9 keV pink beam and a 9.0 and 8.8 keV two-color mode, successfully measuring the temporal ifnromation of the pulses for several different FEL operating conditions. The most interesting achievement is the PALM’s ability to measure two arrival times of the two colorors as tey are shifted against each other by the FEL, opening up new possibilities in temporal accuracy for two-color experiments. SwissFEL will employ two such devices at the end stations for use by both operators and experimenters to improve the operation of the FEL and to better interpret experimental data. References [1]P. N. Juranić et. al, Journal of Instrumentation (2014) 9. [2]T. Ishikawa et. al., Nature Photonics (2012) 6(8). [3] P. N. Juranić et. al., Optics Express (2014) 22.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要