Deformation of polyetheretherketone, PEEK, with different thicknesses

Evaggelia Papia, Sara Anna Caroline Brodde,Jonas Peter Becktor

Journal of the Mechanical Behavior of Biomedical Materials(2022)

引用 4|浏览27
暂无评分
摘要
In order to determine a suitable thickness of polyetheretherketone (PEEK) for manufacturing of surgical membranes, the purpose was to evaluate how different thicknesses of PEEK influence the mechanical properties under flexure and tension. In total 20 specimens in PEEK with two different thicknesses, 0.5 mm and 1.0 mm were fabricated and tested in a three-point flexural strength test and tensile strength test (n = 5 specimens). Statistical analysis was done with non-parametric Mann-Whitney test with level of significance α = 0.05, for both material tests, respectively. The 1.0 mm-thick samples resulted in higher values in elastic limit and conventional deflection (Sc-value) in the flexural strength test compared to 0.5 mm-thick samples. In the tensile strength test, the results did not show any significant difference in elastic limit depending on the thickness evaluated. However, PEEK with thickness of 1.0 mm received significantly higher maximum value at fracture. Within the limitations of this study, PEEK with a thickness of 0.5 mm–1.0 mm shows mechanical properties that are appropriate thickness and can meet the complex demands for dimensioning of surgical membranes.
更多
查看译文
关键词
Bone augmentation,Guided tissue regeneration,Membranes,Polyetheretherketone,PEEK