Iatrogenic tibial arteriovenous fistula after Fogarty balloon catheter graft thrombectomy

CLINICAL CASE REPORTS(2021)

引用 1|浏览6
暂无评分
摘要
A 75-year-old male presented with an immediately threatened grade IIb acute ischemia of the left leg due to thrombosis of a femoro-infrapopliteal prosthetic bypass graft. After an urgent Computed Tomography Angiography, an urgent graft thrombectomy was performed using a 5 Fr Fogarty catheter, which had a troublesome distal passage, causing a tibial A-V fistula.
更多
查看译文
关键词
arteriovenous fistula, fogarty thrombectomy, graft thrombectomy, iatrogenic injury