Clinical utility of 3D magnetic resonance elastography in patients with biliary obstruction

EUROPEAN RADIOLOGY(2021)

引用 3|浏览2
暂无评分
摘要
Objectives Three-dimensional magnetic resonance elastography (3D-MRE) allows for multiparametric modeling of both elastic and viscous tissue characteristics. Our aim was to compare 3D-MRE with conventional liver shear stiffness assessment in gauging obstructive jaundice (OJ), predicting the adequacy of biliary decompression after drainage, and discriminating OJ from liver fibrosis. Methods Patients with no histories of liver disease ( n = 201) were studied in retrospect, grouped by bilirubin levels as no jaundice (NJ ≤ 2 mg/dL; n = 75), mild OJ (>2 mg/dL and ≤ 4 mg/dL; n = 56), and severe OJ (> 4 mg/dL; n = 70). For comparison, another 75 patients with chronic hepatitis B and C infections and histologically proven liver fibrosis were similarly analyzed. Each patient underwent spin-echo echo-planar-imaging MRE at 60 Hz with 3D wave postprocessing. Logistic regression and ordinary regression models were used to compare the 3D-MRE model with liver shear stiffness. Results Liver shear stiffness, loss modulus, and damping ratio were incorporated into a 3D-MRE model, which significantly outperformed shear stiffness in predicting OJ severity (accuracy: 0.801 vs 0.672; p < 0.001). Both the 3D-MRE model and liver shear stiffness performed equally well in predicting the outcome of biliary drainage procedure ( C -statistics: 0.852 vs 0.847; p = 0.48). The 3D-MRE model also demonstrated significantly better C -statistics than that of liver shear stiffness in discriminating mild OJ from F1–F2 liver fibrosis (0.765 vs 0.641; p = 0.005) and severe OJ from F3–F4 liver fibrosis (0.750 vs 0.635; p = 0.031). Conclusions 3D-MRE is an innovative imaging method for gauging OJ severity, predicting the outcome of biliary drainage procedure, and discriminating OJ from liver fibrosis. Key Points • 3D-MR elastography achieved promising results for predicting the severity of obstructive jaundice. • Advanced parameters of 3D-MR elastography demonstrated significantly better performance than that of shear stiffness of 2D-MR elastography in discriminating obstructive jaundice from liver fibrosis caused by chronic hepatitis B/C. • Both 3D-MR elastography and 2D-MR elastography were equivalent in predicting the outcome of biliary drainage procedure.
更多
查看译文
关键词
Magnetic resonance imaging, Elasticity imaging techniques, Jaundice, obstructive, Biomarkers
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要