Quantitative EEG-Based Seizure Estimation in Super-Refractory Status Epilepticus

Neurocritical Care(2021)

引用 7|浏览2
暂无评分
摘要
Background The objective of this study was to evaluate the accuracy of seizure burden in patients with super-refractory status epilepticus (SRSE) by using quantitative electroencephalography (qEEG). Methods EEG recordings from 69 patients with SRSE (2009–2019) were reviewed and annotated for seizures by three groups of reviewers: two board-certified neurophysiologists using only raw EEG (gold standard), two neurocritical care providers with substantial experience in qEEG analysis (qEEG experts), and two inexperienced qEEG readers (qEEG novices) using only a qEEG trend panel. Results Raw EEG experts identified 35 (51%) patients with seizures, accounting for 2950 seizures (3,126 min). qEEG experts had a sensitivity of 93%, a specificity of 61%, a false positive rate of 6.5 per day, and good agreement ( κ = 0.64) between both qEEG experts. qEEG novices had a sensitivity of 98.5%, a specificity of 13%, a false positive rate of 15 per day, and fair agreement ( κ = 0.4) between both qEEG novices. Seizure burden was not different between the qEEG experts and the gold standard (3,257 vs. 3,126 min), whereas qEEG novices reported higher burden (6066 vs. 3126 min). Conclusions Both qEEG experts and novices had a high sensitivity but a low specificity for seizure detection in patients with SRSE. qEEG could be a useful tool for qEEG experts to estimate seizure burden in patients with SRSE.
更多
查看译文
关键词
Status epilepticus, Super-refractory status epilepticus, Electroencephalogram, Quantitative electroencephalography, Seizure burden
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要