Comparison Of Supercritical Co2 Power Cycles To Steam Rankine Cycles In Coal-Fired Applications

PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 9(2017)

引用 4|浏览1
暂无评分
摘要
Increasing the efficiency of coal-fired power plants is vital to reducing electricity costs and emissions. Power cycles employing supercritical carbon dioxide (sCO(2)) as the working fluid have the potential to increase power cycle efficiency by 3 - 5% points over state-of-the-art oxy-combustion steam-Rankine cycles operating under comparable conditions. To date, the majority of studies have focused on the integration and optimization of sCO(2) power cycles in waste heat, solar, or nuclear applications.The goal of this study is to demonstrate the potential of sCO(2) power cycles, and quantify the power cycle efficiency gains that can be achieved versus the state-of-the-art steam-Rankine cycles employed in oxy-fired coal power plants. Turbine inlet conditions were varied among the sCO(2) test cases and compared with existing Department of Energy (DOE)/National Energy Technology6 Laboratory (NETL) steam base cases. Two separate sCO(2) test cases were considered and the associated flow sheets developed. The turbine inlet conditions for this study were chosen to match conditions in a coal-fired ultra-supercritical steam plant (T-inlet = 593 degrees C, P-inlet = 24.1 MPa) and an advanced ultra-supercritical steam plant (T-inlet=730 degrees C, P-inlet = 27.6 MPa). A plant size of 550 MWe, was selected to match available information on existing DOE/NETL bases cases.The effects of cycle architecture, combustion-air preheater temperature, and cooling source type were considered subject to comparable heat source and reference conditions taken from the steam Rankine reference cases. Combinations and variants of sCO(2) power cycles-including cascade and recompression and variants with multiple reheat and compression steps-were considered with varying heat-rejection subsystems-air-cooled, direct cooling tower, and indirect-loop cooling tower. Where appropriate, combustion air preheater inlet temperature was also varied.Through use of a multivariate nonlinear optimization design process that considers both performance and economic impacts, curves of minimum cost versus efficiency were generated for each sCO(2) test case and combination of architecture and operational choices. These curves indicate both peak theoretical efficiency and suggest practical limits based on incremental cost versus performance. For a given test case, results for individual architectural and operational options give insight to cost and performance improvements from step-changes in system complexity and design, allowing down selection of candidate architectures. Optimized designs for each test case were then selected based on practical efficiency limits within the remaining candidate architectures and compared to the relevant baseline steam plant. sCO(2) cycle flowsheets are presented for each optimized design.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要