谷歌浏览器插件
订阅小程序
在清言上使用

Assessing Impedance in Heart Failure

Circulation Heart Failure(2016)

引用 0|浏览0
暂无评分
摘要
HomeCirculation: Heart FailureVol. 9, No. 1Assessing Impedance in Heart Failure Free AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessEditorialPDF/EPUBAssessing Impedance in Heart FailureFrom Device Diagnostics to Population Health Opportunities? Roy S. Small, MD and W.H. Wilson Tang, MD Roy S. SmallRoy S. Small From The Heart Group of Lancaster General Hospital, Lancaster, PA (R.S.S.); and Heart and Vascular Institute, Cleveland Clinic, OH (W.H.W.T.). and W.H. Wilson TangW.H. Wilson Tang From The Heart Group of Lancaster General Hospital, Lancaster, PA (R.S.S.); and Heart and Vascular Institute, Cleveland Clinic, OH (W.H.W.T.). Originally published23 Dec 2015https://doi.org/10.1161/CIRCHEARTFAILURE.115.002761Circulation: Heart Failure. 2016;9Heart failure care is expensive and resource intensive. In the era of population medicine, accountable care organizations, and bundled care, an inexpensive noninvasive technique to facilitate the management of this population would be a valuable asset. Although continuous remote monitoring of pulmonary artery pressure (PAP) is available and proven to improve outcomes in the clinical trial setting,1 it is invasive and expensive to implant and requires dedicated personnel to routinely monitor the patient, interpret the data, and consistently use the information. Indeed, few practices are prepared for the type of infrastructure investment required to effectively monitor PAP at the present time under the current payment model. Hence, the adoption of PAP monitoring has been slow and likely limited to patients with advanced heart failure within health systems with sophisticated heart failure programs. Unlike cardiac implantable electronic devices, current trends indicate that PAP monitoring will be used more commonly in patients with heart failure and a preserved ejection fraction because this is a group that is most difficult to manage and accounts for the majority of readmissions.See Article by Zile et alImpedance measurements from cardiac implantable electronic devices have been clinically available for over a decade. The scientific principle underlying the measurement of impedance, which is the biological equivalent of resistance, is Ohm's law: R=V/I. Resistance (R) is a function of the relationship between the applied voltage (V) and the current (I) measured across an electric field.2 In patients with cardiac implantable electronic devices that can measure impedance, the electric field includes the lung and thoracic tissue that lie between the device and the tip of the pacing electrode. Presumably, a congested chest has higher fluid content and thus a lower resistance (or impedance), as water is a better electric conductor than air.2 Indeed, impedance signals have been demonstrated to track with physiological alterations in heart failure.3 Hence, recognizing alterations in impedance trends may uncover vulnerabilities that can be associated with adverse clinical events.4–7 Meanwhile, accessing the information requires no special equipment or complex logistics, and there is no additional cost. In fact, the data are already incorporated into routine remote and in-person cardiac implantable electronic device checks. Nonetheless, the majority of patients in whom these devices are currently implanted do not have the information reviewed as a part of their routine follow-up. In part, the resistance to using these data has been a reflection of the healthy skepticism of practicing physicians. The concept of impedance is not intuitive. Initial attempts to measure thoracic impedance using surface electrodes (BioZ) proved unreliable because of the low signal:noise ratio such that changes in the impedance signal were obscured by small variances in lead position or skin preparation. Physiological changes other than congestion will affect impedance, and there is a low frequency of false-positive findings (low impedance without clinical congestion) that has been difficult to explain. Furthermore, the literature has not supported the routine monitoring of thoracic impedance using implanted devices. Enabling an automatic alert to notify providers of device-detected fluid-related changes may paradoxically increase costs without providing substantial clinical benefit.8 In addition, billing guidelines require coordination between the electrophysiology service and heart failure programs to avoid inappropriate charges and can be intimidating. Specifically, the electrophysiology-related and heart failure–monitored physiological parameters (including impedance) have distinct billing codes and are reimbursed separately. There are also time parameters, which limit the frequency of payment when monitoring is performed remotely. Furthermore, clinic logistics may need to be adjusted so that device interrogations do not interfere with established workflows. Patients with impedance measuring devices should be identified before seeing the provider. Technicians can independently interrogate the device (or download data from a website), which generates the report so that disruptions of patient flow are avoided. Taken together, the practical result of these concerns and challenges has been that physiological parameters generated by implanted devices have been underused and thoracic impedance oftentimes ignored.Some of the confusion on impedance data from implanted devices is related to a misunderstanding of its utility. Unlike PAP, impedance is not necessarily actionable. PAP is the potassium of congestion. It is an absolute measurement, which can be treated directly. Impedance is more analogous to creatinine. Is creatinine important? Definitely. However, it is a prognostic marker and an indirect signal, which may or may not warrant changes in therapy or alter the natural history despite its prognostic value. What we have learned is that impedance is probabilistically predictive, but not necessarily prescriptive. Although there are certainly instances when abnormally low impedance will help in the detection of subtle congestion, there are also false-positives, which can be misleading. Ideally, impedance measurements should be interpreted along with clinical data and other measures of device and cardiac function.In this issue of Circulation: Heart Failure, Zile et al9 report a retrospective analysis of a large data bank correlating device-derived absolute impedance measurements and subsequent Medicare-reported outcomes. Patients were empirically divided into 3 groups (low, medium, and high impedance) after a 6-month censored period to allow for signal stabilization. Those with the lowest averaged impedance measurements 6 to 9 months post implant had the highest mortality. Patients with the highest impedance had the lowest mortality, and those with an intermediate range measurement had a corresponding midrange mortality risk. Changes between the baseline and the subsequent measurements at 9 to 12 months post implant added predictive value.9 In contrast to previous study, which have examined the calculated impedance trends and mortality relationship,6 impedance measurements from the first 6 months after implant were censored in this study to allow time for the signal to stabilize and no algorithmic manipulation of the data was performed. Various measurement intervals were examined. Averaged impedance measurements over periods as brief as 1 day provided important prognostic information. These results add support to the concept that changes in device-monitored physiological parameters (specifically impedance) can track with patient outcomes on rehospitalization, decompensation, and mortality. It offers a simplified and more usable context in that impedance alone has prognostic value whether measured on a single day or serially over several months.So, how do we interpret the findings in the context of previous neutral (if not negative) trial data, and how can we begin to incorporate this information into clinical practice? And can we use these data to actually affect outcomes or simplify practice? It is important to emphasize that routine monitoring of impedance from implanted devices has not been proven to improve individual clinical outcomes. However, this does not mean that such information cannot be used for population health management. Unlike a drug or the device itself, a diagnostic tool will not change outcome, but relies on interpretation, communication, and patient compliance to effect change. Thus, it has been much harder to demonstrate that proactive monitoring of impedance can change individual outcomes than it has been to demonstrate that impedance predicts population outcomes. As Zile et al9 demonstrate, stable or increasing impedance indicates a better prognosis and thus less intense follow-up might be appropriate. Limiting routine monitoring to high-risk patients (recent hospitalization, chronic noncompliance, or those requiring frequent diuretic adjustments) might be a cost-effective intervention. If we accept that impedance can identify high-risk profiles, then there are ways to use the information to simplify practice in population health perspectives. Changes in impedance might influence the frequency of clinic appointments either remotely or in person. Falling impedance might prompt case review with the potential for recommending more frequent follow-up to uncover early decompensation or poor compliance. What has not been traditionally tested in clinical studies but is highly relevant to appropriate allocations of scarce resources is the ability to proactively provide palliative care options as a care management strategy. Specifically, patients with progressively declining or persistently low impedance despite all attempts to optimize medications and ancillary therapies might identify a subgroup in which end-of-life discussions should be considered. Although economically and logistically challenging, future studies should examine the opportunity on whether these data can be used to improve outcomes and deliver more cost effective care delivery on a population basis in addition to that offered by individual clinicians.Sources of FundingDr Tang receives grant support from the National Institutes of Health.DisclosuresDr Tang has previously served as Principal Investigator of a clinical trial sponsored by Medtronic Inc. Dr Small has received honorarium and is a consultant to Medtronic. He is the medical codirector of a Medtronic-owned home monitoring service.FootnotesThe opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.Correspondence to Roy S. Small, MD, The Heart Group of Lancaster General Health, 217 Harrisburg Ave, Lancaster, PA 17603. E-mail [email protected]References1. Abraham WT, Adamson PB, Bourge RC, Aaron MF, Costanzo MR, Stevenson LW, Strickland W, Neelagaru S, Raval N, Krueger S, Weiner S, Shavelle D, Jeffries B, Yadav JS; CHAMPION Trial Study Group. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial.Lancet. 2011; 377:658–666. doi: 10.1016/S0140-6736(11)60101-3.CrossrefMedlineGoogle Scholar2. Tang WH, Tong W. Measuring impedance in congestive heart failure: current options and clinical applications.Am Heart J. 2009; 157:402–411. doi: 10.1016/j.ahj.2008.10.016.CrossrefMedlineGoogle Scholar3. Rademaker MT, Charles CJ, Melton IC, Richards AM, Frampton CM, Siou J, Qu F, Eigler NL, Gutfinger D, Troughton RW. Monitoring of heart failure: comparison of left atrial pressure with intrathoracic impedance and natriuretic peptide measurements in an experimental model of ovine heart failure.Clin Sci (Lond). 2011; 120:207–217. doi: 10.1042/CS20100388.CrossrefMedlineGoogle Scholar4. Small RS, Whellan DJ, Boyle A, Sarkar S, Koehler J, Warman EN, Abraham WT. Implantable device diagnostics on day of discharge identify heart failure patients at increased risk for early readmission for heart failure.Eur J Heart Fail. 2014; 16:419–425. doi: 10.1002/ejhf.48.CrossrefMedlineGoogle Scholar5. Small RS, Wickemeyer W, Germany R, Hoppe B, Andrulli J, Brady PA, Labeau M, Koehler J, Sarkar S, Hettrick DA, Tang WH. Changes in intrathoracic impedance are associated with subsequent risk of hospitalizations for acute decompensated heart failure: clinical utility of implanted device monitoring without a patient alert.J Card Fail. 2009; 15:475–481. doi: 10.1016/j.cardfail.2009.01.012.CrossrefMedlineGoogle Scholar6. Tang WH, Warman EN, Johnson JW, Small RS, Heywood JT. Threshold crossing of device-based intrathoracic impedance trends identifies relatively increased mortality risk.Eur Heart J. 2012; 33:2189–2196. doi: 10.1093/eurheartj/ehs121.CrossrefMedlineGoogle Scholar7. Tang WH, Wickemeyer WJ, Germany RE, Hoppe BL, Andriulli JA, Brady PA, Sarkar S, Hettrick DA, Small RS. Uncovering interim clinical events at the time of clinical encounter by reviewing intrathoracic impedance threshold crossings.J Card Fail. 2011; 17:893–898. doi: 10.1016/j.cardfail.2011.07.005.CrossrefMedlineGoogle Scholar8. van Veldhuisen DJ, Braunschweig F, Conraads V, Ford I, Cowie MR, Jondeau G, Kautzner J, Aguilera RM, Lunati M, Yu CM, Gerritse B, Borggrefe M; DOT-HF Investigators. Intrathoracic impedance monitoring, audible patient alerts, and outcome in patients with heart failure.Circulation. 2011; 124:1719–1726. doi: 10.1161/CIRCULATIONAHA.111.043042.LinkGoogle Scholar9. Zile MR, Sharma V, Johnson JW, Warman EN, Baicu CF, Bennett TD. Prediction of all-cause mortality based on the direct measurement of intrathroacic impedance.Circ Heart Fail. 2016; 9:e002543. doi: 10.1161/CIRCHEARTFAILURE.115.002543.LinkGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Bachtiger P, Plymen C, Pabari P, Howard J, Whinnett Z, Opoku F, Janering S, Faisal A, Francis D and Peters N (2020) Artificial Intelligence, Data Sensors and Interconnectivity: Future Opportunities for Heart Failure, Cardiac Failure Review, 10.15420/cfr.2019.14, 6 January 2016Vol 9, Issue 1 Advertisement Article InformationMetrics © 2015 American Heart Association, Inc.https://doi.org/10.1161/CIRCHEARTFAILURE.115.002761PMID: 26699395 Originally publishedDecember 23, 2015 Keywordspatient readmissionhealth care utilizationelectric impedanceheart failureprognosisEditorialsPDF download Advertisement SubjectsHeart Failure
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要