Updates on the X-Pinch Platform and Faraday Rotation Imaging Diagnostic on the Maize Pulsed Power Facility *

international conference on plasma science(2021)

引用 1|浏览3
暂无评分
摘要
X-pinches, formed by driving intense current through the crossing of 2 or more wires, provide an excellent platform for the study of due to their propensity to generate a single micro-pinch at a predetermined location in space (i.e., where the wires cross) [1] , [2] . Ideally, micropinches are areas of run-away compression to very small radii (~1 µm) leading to pressures on the order of ~1 Gbar for currents on the order of ~0.1 MA. However, the fraction of the total current that is driven through the dense micro-pinch plasma at small radii versus that being shunted through the surrounding coronal plasma at larger radii is not well known. To allow for the study of micro-pinches and their current distribution on the 1-MA MAIZE facility, a Faraday rotation imaging diagnostic (1064 nm) [3] , as well as a corresponding modular X-pinch load hardware, were developed. Presented is the status of these developments including preliminary experimental results characterizing X-pinches on the MAIZE LTD.
更多
查看译文
关键词
maize pulsed power facility,X-pinches,micropinches,wires cross,micropinch plasma,surrounding coronal plasma,larger radii,current distribution,1-MA MAIZE facility,Faraday rotation imaging diagnostic,modular X-pinch load hardware,radius 1.0 mum,current 0.1 MA,size 1064.0 nm