Allergic Contact Dermatitis, an Important Skin Reaction in Diabetes Device Users: A Systematic Review

DERMATITIS(2022)

引用 8|浏览2
暂无评分
摘要
Diabetes management has undergone many advances over the years, including the introduction of devices that allow patients to monitor blood glucose and administer insulin. Although these devices have improved patients' quality of life, they are associated with adverse reactions. A systematic literature search was performed up to May 2020 in PubMed, Cochrane, and Embase databases, with no temporal restrictions. Articles were screened by title, abstract, and full text as needed. A manual search among the references of the included articles was also performed. Two hundred sixty-five articles were identified, and 50 studies met inclusion criteria. Several cases of allergic contact dermatitis due to the use of insulin infusion systems and blood glucose monitoring have been reported. Acrylates, methacrylates, and colophonium, as well as, in particular, isobornyl acrylate, represent the main allergens responsible. Skin reactions, in particular allergic contact dermatitis, are a very common adverse event caused by insulin pumps and glucose sensors, which may lead to discontinue the usage of these devices with serious consequences for the patients. Collaboration between specialists, specifically between dermatologists and diabetologists, with patients and manufacturers is essential for the correct management of diabetes devices and potential related skin reactions.