Investigation of a Cherenkov-based gamma-ray diagnostic for measurement of 17 MeV gamma-rays from T(D, γ)5He in magnetic confinement fusion plasmas

Journal of Instrumentation(2022)

引用 4|浏览8
暂无评分
摘要
Abstract At present, the only method for assessing the fusion power throughput of a reactor relies on the absolute measurement of 14 MeV neutrons produced in the D-T nuclear reaction. For ITER and DEMO, however, at least another independent measurement of the fusion power is required. The 5 He * nucleus produced in the D-T fusion reaction has two de-excitation channels. The most likely is its disintegration in an alpha particle and a neutron, D + T → 5 He * → α + n, by means of the nuclear force. There is however also an electromagnetic channel, with a branching ratio ∼10 −5 , which leads to the emission of a 17 MeV gamma-ray, i.e. D + T → 5 He * → 5 He + γ . The detection of this gamma-ray emission could serve as an independent method to determine the fusion power. In order to enable 17 MeV gamma-ray measurements, there is need for a detector with some coarse energy discrimination and, most importantly, capable of working in a neutron-rich environment. Conventional inorganic scintillators, such as LaBr 3 (Ce), have comparable efficiencies to neutrons and gamma-rays and they cannot be used for 17 MeV gamma-ray measurements without significant neutron shielding. In order to overcome this limitation, we here propose the conceptual design of a gamma-ray counter with a variable energy threshold based on the Cherenkov effect and designed to operate in intense neutron fields. The detector geometry has been optimized using Geant4 so to achieve a gamma-ray to neutron efficiency ratio better than 10 5 . The design is based on a gas Cherenkov detector and the photo-sensor is still to investigated.
更多
查看译文
关键词
Cherenkov and transition radiation, Gaseous detectors, Nuclear instruments and methods for hot plasma diagnostics, Gamma detectors (scintillators, CZT, HPGe, HgI etc.)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要