C31 update on supra–annular sizing of transcatheter aortic valve prostheses in raphe–type bicuspid aortic valve disease according to the lira method

EUROPEAN HEART JOURNAL SUPPLEMENTS(2022)

引用 4|浏览9
暂无评分
摘要
Abstract Aims Recent evidences have shown that transcatheter heart valve (THV) anchoring in BAV patients might occur at the raphe–level, known as the LIRA (Level of Implantation at the RAphe) plane. A novel supra–annular sizing method based on the measurement of the perimeter at the raphe–level (LIRA–method) was shown to be safe and effective in 20 consecutive BAV patients with severe aortic stenosis. The purpose of this study was to confirm the safety and the efficacy of the LIRA method in a larger study population. Methods the LIRA plane method was applied to all consecutive patients with raphe–type BAV disease between November 2018 to October 2021 in our centre. We prospectively sized TAVI prosthesis according to the manufacture recommendations on the basis of baseline CT scan perimeters at the LIRA plane. Post–procedural device success, defined according to Valve Academic Research Consortium–2 (VARC–2) criteria, was evaluated in the overall cohort. Results 50 patients were identified as having a raphe–type BAV disease at pre–TAVI CT scans. Mean patient age was 80 ± 6.2 years. Three different BAV anatomies (47 patients with BAV type 1 and 3 patients with BAV type 2) were implanted with different types of TAVI prostheses (28 Acurate Neo/Neo 2, 21 Core Valve Evolut R/Pro,1 Lotus) sized prospectively according to the LIRA plane method. In all patients, there was a significant discrepancy between LIRA and virtual basal ring (VBR) (mean perimeter LIRA 73.1 ± 8.3 mm vs mean perimeter VBR 81.5 ± 6.6 mm; p < 0.001). The median prosthesis size was 26 mm (23–27). Pre–dilatation was frequently performed (88%) with a median balloon size of 20 mm (20–23), whereas post–dilatation was applied in 26% of the cases with a median balloon size of 23 mm (22–24). The LIRA plane method appeared to be highly successful (100% VARC–2 device success) with no procedural mortality, no valve migration, residual trivial/mild paravalvular leak with no cases of moderate–severe regurgitation and no cases of mean gradient >20 mmHg pre–discharge. The rate of new pacemaker implantation was 10%. Conclusions Supra–annular sizing according to the LIRA plane method confirmed to be safe with a high device success in a larger study population. The application of the LIRA plane method might optimize TAVI prosthesis sizing in patients with raphe–type BAV disease.
更多
查看译文
关键词
bicuspid aortic valve disease, TAVR, MDCT, TAVR prostheses sizing, LIRA method
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要