Comparative analysis of two-level and three-level multilevel inverter for electric vehicle application using BLDC motor drive

CIRCUIT WORLD(2023)

引用 1|浏览1
暂无评分
摘要
Purpose The conventional two-level inverter suffers from harmonics, higher direct current (DC) link voltage requirement, higher dv/dt and heating of the rotor. This study aims to overcome by using a multilevel inverter for brushless DC (BLDC) drive. Design/methodology/approach This paper presents a comparative analysis of the conventional two-level and three-level multilevel inverter for electric vehicle (EV) application using BLDC drive. Findings A three-level Active Neutral Point Clamped Multilevel inverter (ANPCMLI) is proposed in this paper which provides DC link voltage control. Simulation studies of the multilevel inverter and BLDC motor is carried out in MATLAB. Originality/value The ANPCMLI fed BLDC simulation results shows that there is the significant reduction in the BLDC motor torque ripple, switching stress and harmonic distortion in the BLDC motor fed ANPCMLI compared to the conventional two-level inverter. A prototype of ANPCMLI fed BLDC drive along with field programmable gate array (FPGA) control is built and MATLAB simulation results are verified experimentally.
更多
查看译文
关键词
Brushless DC motor, Field programmable gate array, Active neutral point clamped multilevel inverter