谷歌浏览器插件
订阅小程序
在清言上使用

Simultaneous Analysis of Mono‐, Di‐, Triacylglycerols, and Fatty Acid Methyl Esters in Biodiesel by Size‐Exclusion Chromatography

European journal of lipid science and technology(2021)

引用 0|浏览3
暂无评分
摘要
The purpose of this study is to develop and validate a method based on size-exclusion chromatography (SEC) for the simultaneous determination of fatty acid methyl esters (FAME), monoacylglycerols (MAG), diacylglycerols (DAG), and triacylglycerols (TAG) in biodiesel. The proposed method presents good linearity. The limits of detection are 0.26% mass for FAME, 0.02% mass for MAG, 0.01% mass for DAG, and 0.02% mass for TAG. The limits of quantification are 0.78% mass for FAME, 0.06% mass for MAG, 0.01% mass for DAG, and 0.06% mass for TAG. Accuracy evaluated by recovery yielded values ranging from 98.93% to 117.67%. Precision is evaluated by repeatability (%), which is ranged from 0.03% to 13.67%. The proposed SEC method proves effective in determining the FAME, MAG, DAG, and TAG content of standard samples, and the paired t-test shows that the results obtained were statistically similar to the gas chromatography (GC) values. The method also has some advantages over the reference GC methods, since it obtains the content for each class analyzed, irrespective of its components. Also, it does not require derivatization, which makes it easier and also quicker (15 min) than the 60 min taken by the two reference methods, and it does not need an internal standard, which makes it cheaper. Practical Applications: Size exclusion chromatography (SEC) is an efficient method for simultaneous and quantitative determination of fatty acid methyl esters (FAME), monoacylglycerols (MAG), diacylglycerols and triacylglycerols (TAG). The method present itself as an alternative to reference methods (ASTM D 6584 and ABNT NBR 15764) based on gas chromatography (GC). The proposed method shows advantages compared to reference methods, once it makes possible to determine the content of each constituent class in samples, regardless of its components, what makes the peak integration easier. Beyond that, previous sample derivatization is unnecessary, what makes the method simpler, cheaper and faster (15 min) than both reference methods that demands together 60 min for analysis (ASTM D 6584 for MAG, DAGa and TAG and ABNT NBR 15764 for FAME analysis).
更多
查看译文
关键词
acylglycerols,biodiesels,fatty acid methyl esters,size-exclusion chromatography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要