Implantation of a Leadless Pacemaker after Incomplete Transvenous Lead Extraction in a 90-Year-Old Pacemaker-Dependent Patient

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH(2022)

引用 0|浏览0
暂无评分
摘要
Transluminal lead extraction (TLE) is a well-established procedure for the removal of damaged or infected pacing systems. Despite its high efficacy, the procedure is associated with significant risks, some of which may contribute to severe life-threatening complications. Herein, we present the case of a 90-year-old female who was 100% pacemaker-dependent (PM-dependent) and had ventricular lead fragmentation after the TLE procedure. In this elderly patient, after taking into account the whole clinical context-age, frailty syndrome, infection, and high peri- and postprocedural risks-we decided on MICRA VR implantation as well as leaving the remains of the ventricular lead in the right heart chambers. A Leadless pacemaker (LP) is an excellent alternative to PM-dependent individuals, in whom implantation of permanent transvenous PM is precluded due to multiple infectious and non-infectious issues.
更多
查看译文
关键词
transluminal lead extraction,leadless pacemaker,MICRA VR
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要