Reversible Thermo-Responsive Valve for Microfluidic Paper-Based Analytical Devices

MICROMACHINES(2022)

引用 3|浏览12
暂无评分
摘要
Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (mu PADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32 degrees C and more pores were opened at temperatures above 32 degrees C. Valve permeability tests confirmed that the proposed polymerized membrane was impermeable to water and proteins at temperatures below 32 degrees C and permeable to water at temperatures above 32 degrees C. The valve could also be reversibly and repeatedly opened and closed by changing the temperature near 32 degrees C. These results suggest that plasma-induced graft polymerization may be used to produce thermo-responsive valves that can be opened and closed without subsequent loss of performance. These results indicate that the thermo-responsive valve fabricated by plasma-induced graft polymerization could potentially be applied to ELISA with mu PADs.
更多
查看译文
关键词
microfluidic paper-based analytical devices, thermo-responsive polymer, poly(N-isopropylacrylamide), valve, plasma-induced graft polymerization