谷歌浏览器插件
订阅小程序
在清言上使用

Comparison of rhinomanometric and computational fluid dynamic assessment of nasal resistance with respect to measurement accuracy

International Journal of Computer Assisted Radiology and Surgery(2022)

引用 3|浏览16
暂无评分
摘要
Purpose Computational fluid dynamics (CFD)-based calculation of intranasal airflow became an important method in rhinologic research. Current evidence shows weak to moderate correlation as well as a systematic underprediction of nasal resistance by numerical simulations. In this study, we investigate whether these differences can be explained by measurement uncertainties caused by rhinomanometric devices and procedures. Furthermore, preliminary findings regarding the impact of tissue movements are reported. Methods A retrospective sample of 17 patients, who reported impaired nasal breathing and for which rhinomanometric (RMM) measurements using two different devices as well as computed tomography scans were available, was investigated in this study. Three patients also exhibited a marked collapse of the nasal valve. Agreement between both rhinomanometric measurements as well as between rhinomanometry and CFD-based calculations was assessed using linear correlation and Bland–Altman analyses. These analyses were performed for the volume flow rates measured at trans-nasal pressure differences of 75 and 150 Pa during inspiration and expiration. Results The correlation between volume flow rates measured using both RMM devices was good ( R 2 > 0.72 for all breathing states), and no relevant differences in measured flow rates was observed (21.6 ml/s and 14.8 ml/s for 75 and 150 Pa, respectively). In contrast, correlation between RMM and CFD was poor ( R 2 < 0.5) and CFD systematically overpredicted RMM-based flow rate measurements (231.8 ml/s and 328.3 ml/s). No differences between patients with and without nasal valve collapse nor between inspiration and expiration were observed. Conclusion Biases introduced during RMM measurements, by either the chosen device, the operator or other aspects as for example the nasal cycle, are not strong enough to explain the gross differences commonly reported between RMM- and CFD-based measurement of nasal resistance. Additionally, tissue movement during breathing is most likely also no sufficient explanation for these differences.
更多
查看译文
关键词
Computational fluid dynamics, Nasal breathing, Nasal obstruction, Rhinomanometry, Computed tomography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要