谷歌浏览器插件
订阅小程序
在清言上使用

Correction To: Muscle B Mode Ultrasound and Shear-Wave Elastography in Idiopathic Inflammatory Myopathies (SWIM): Criterion Validation Against MRI and Muscle Biopsy Findings in an Incident Patient Cohort

BMC RHEUMATOLOGY(2022)

引用 1|浏览12
暂无评分
摘要
Background B mode ultrasound (US) and shear wave elastography (SWE) are easily accessible imaging tools for idiopathic inflammatory myopathies (IIM) but require further validation against standard diagnostic procedures such as MRI and muscle biopsy. Methods In this prospective cross-sectional study we compared US findings to MRI and muscle biopsy findings in a group of 18 patients (11 F, 7 M) with active IIM (dermatomyositis 6, necrotising autoimmune myopathy 7, inclusion body myositis 4, overlap myositis 1) who had one or both procedures on the same muscle. US domains (echogenicity, fascial thickness, muscle bulk, shear wave speed and power doppler) in the deltoid and vastus lateralis were compared to MRI domains (muscle oedema, fatty infiltration/atrophy) and muscle biopsy findings (lymphocytic inflammation, myonecrosis, atrophy and fibro-fatty infiltration). A composite index score (1–4) was also used as an arbitrary indicator of overall muscle pathology in biopsies. Results Increased echogenicity correlated with the presence of fatty infiltration/atrophy on MRI ( p = 0.047) in the vastus lateralis, and showed a non-significant association with muscle inflammation, myonecrosis, fibrosis and fatty infiltration/atrophy ( p > 0.333). Severe echogenicity also had a non-significant association with higher composite biopsy index score in the vastus lateralis ( p = 0.380). SWS and US measures of fascial thickness and muscle bulk showed poor discrimination in differentiating between pathologies on MRI or muscle biopsy. Power Doppler measures of vascularity correlated poorly with the presence of oedema on MRI, or with inflammation or fatty infiltration on biopsy. Overall, US was sensitive in detecting the presence of muscle pathology shown on MRI (67–100%) but showed poorer specificity (13–100%). Increased echogenicity showed good sensitivity when detecting muscle pathology (100%) but lacked specificity in differentiating muscle pathologies (0%). Most study participants rated US as the preferred imaging modality. Conclusions Our findings show that US, in particular muscle echogenicity, has a high sensitivity, but low specificity, for detecting muscle pathology in IIM. Traditional visual grading scores are not IIM-specific and require further modification and validation. Future studies should continue to focus on developing a feasible scoring system, which is reliable and allows translation to clinical practice.
更多
查看译文
关键词
Shear wave elastography,B mode Ultrasound,Idiopathic inflammatory myopathies,Imaging,Myositis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要