Reliability of the Tibial Tubercle-Roman Arch Distance for Evaluating Tibial Tubercle Malposition and Predicting Patellar Dislocation via Magnetic Resonance Imaging

ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE(2022)

引用 6|浏览14
暂无评分
摘要
Background: The tibial tubercle (TT)-trochlear groove (TT-TG) distance has low reproducibility in patients with a dysplastic trochlea, whereas the clinical value of the TT-posterior cruciate ligament (TT-PCL) distance remains controversial. Purposes: To establish a method to assess the position of the TT on magnetic resonance imaging (MRI) scans using the TT-Roman arch (TT-RA) distance, compare this method with the TT-TG and TT-PCL distance, and provide the pathological threshold value of the TT-RA distance in patients with patellar dislocation. Study Design: Cross-sectional study; Level of evidence, 3. Methods: The TT-RA distance, TT-TG distance, and TT-PCL distance were measured on MRI scans in 70 patients with a history of patellar dislocation and 70 healthy individuals. Inter- and intraobserver reliability of each measurement parameter were evaluated. The discriminatory capacity and the interrelationship of the 3 measurement parameters were investigated using Pearson correlation and the receiver operating characteristic curve. The pathological threshold values of these measurements were calculated according to the data of healthy individuals. Finally, logistic regression analysis was performed using these values. Results: Patients with patellar dislocation had a greater TT-RA distance compared with healthy individuals (18.05 +/- 4.16 vs 13.86 +/- 2.90 mm; P < .001). The TT-RA distance had a stronger diagnostic capacity, with an area under the curve of 0.802 compared with 0.625 for TT-PCL distance. Excellent reproducibility was seen for TT-RA distance measurement at any degree of trochlear dysplasia (all intraclass correlation coefficients [ICCs] >0.90). The inter- and intraobserver ICCs of the TT-TG distance measurements were extremely low for Dejour type D dysplasia (ICC, 0.509 and 0.616, respectively). The pathological TT-RA distance threshold was calculated as 19.5 mm. Logistic regression showed that patients with a TT-RA distance >19.5 mm were 11.7 times more likely to sustain patellar dislocation than were those with TT-RA distance less than this value. Conclusion: The TT-RA distance was a more reliable parameter with which to evaluate TT position than was TT-TG distance in patients with trochlear dysplasia. The TT-PCL distance was the least reliable among the 3 parameters studied.
更多
查看译文
关键词
MRI, patellar dislocation, tibial tubercle osteotomy, TT-PCL distance, TT-RA distance, TT-TG distance
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要