Feasibility of Novel Software-Based Perfusion Indicators for the Ileal J-Pouch-On the Path towards Objective and Quantifiable Intraoperative Perfusion Assessment with Indocyanine Green Near-Infrared Fluorescence

LIFE-BASEL(2022)

引用 1|浏览10
暂无评分
摘要
Background: In restorative proctocolectomy with ileal J-pouch, perfusion assessment is vital to prevent complications such as anastomotic leak (AL). Indocyanine green near-infrared fluorescence (ICG-NIRF) is gaining popularity, while its interpretation and relevance remain subjective. This study aimed to evaluate a standardized ICG-NIRF imaging protocol combined with a novel, software-based assessment to detect areas of impaired perfusion and a possible correlation with AL of the pouch. Methods: In this prospective study, patients undergoing ileal J-pouch for ulcerative colitis at an inflammatory bowel disease (IBD) referral center were included. Intraoperatively, strictly standardized ICG-NIRF visualization was performed and video-recorded. Postoperatively, a specific software was utilized to determine the change in fluorescence intensity per second (i/s) for systematic regions of interest, generating perfusion-time curves and a pixel-to-pixel map. These were analysed in detail and correlated with clinical outcome (primary end point: AL within 30 days; clearly defined and screened for by pouchoscopy). Results: Four out of 18 included patients developed AL of the ileal pouch-anal anastomosis (IPAA). In the AL group, the perfusion curves on the area adjacent to the IPAA (pouch apex) displayed considerably lower ingress/inflow (median = 1.7; range = 8.5; interquartile-range = 3.8 i/s) and egress/outflow (median = -0.1; range = 0.7; interquartile-range = 0.5 i/s) values than in the non-AL group (ingress: median = 4.3; range = 10.3; interquartile-range = 4.0 i/s); egress: median = (-1.1); range = 3.9; interquartile range = 1.0 i/s). This was confirmed by further novel parameters of pouch perfusion (maximum ingress; maximum egress) and pixel-to-pixel analysis. Conclusions: This study presents the feasibility of a novel methodology to precisely assess pouch perfusion with ICG-NIRF, identifying comparable, quantifiable, and objective parameters to potentially detect perfusion-associated complications in surgery in real-time.
更多
查看译文
关键词
J-pouch, IPAA, anastomotic leak, ulcerative colitis, restorative proctocolectomy, perfusion assessment, indocyanine green, ICG, near-infrared fluorescence, pixel-to-pixel perfusion mapping, perfusion-time curve
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要